The duty cycle of the lubrication pump can be controlled by the main PLC or a separate controller.
Equipped with a pressure regulating valve device, the working pressure of the lubrication pump can be independently set to ensure safe operation.
An exhaust valve arrangement is provided to eliminate lubrication of the air in the pump chamber and to ensure that the lubrication pump drains the oil smoothly.
For low oil level transmitters, normally open or normally closed contacts can be selected depending on the system.
The lubrication system is equipped with a pressure switch, which can effectively monitor the pipeline system to interrupt the flow, leakage and other pressure shortages.
The use of canned grease can reduce impurities, mix in grease and be easy to replace without polluting the environment.
No pressure relief valve device in resistance system, used with GSA/GPA/GPB/GPC/GPD distributor.